Input Output Power Controller
The IOPC is an all in one Power Control device with direct connection of:
- Main power input (18..420 VAC)
- Load output 8 Amp (resistant load)
- 2 Thermocouple inputs (redundancy)
- 1 maximum temperature safety switch input (NC clixon)
- RS485
- Device power 12..24VDC
By the RS485 BUS several IOPC-slaves can be connected to a IOPC-master with Ethernet connection to the local PC or control room.
This makes it very easy to set up a multi zone heating system. Just connect all the wires (by connectors) and plug in the device. Additional safety according local requirements like a main switch and RCD. Operated with a local PC or in the control room.